  4.      International Business Machines Corporation; MS DOS, OS2 and PC DOS 
  5.      are registered trademarks of Microsoft Corporation.
  6.      
  7.                                    WD1003-RAH
  8.      
  9.                                    User Guide
  10.      
  11.      
  12.      The WD1003-RAH controller is designed to interface with up to two 
  13.      Winchester ST506/ST412 RLL type hard disk drives in an IBM PC AT or 
  14.      compatible system and will support drives with up to 16 read/write 
  15.      heads and 2048 cylinders.  Each drive may be a different 
  16.      configuration.  With the 2, 7 RLL encoding feature of the WD1003-RAH, 
  17.      up to 50% more data can be compacted onto a certified RLL hard disk 
  18.      drive using a 26 sectors per track format.
  19.      
  20.                                       NOTE
  21.      
  22.             DO NOT USE THE WD1003-RAH WITH MFM TYPE HARD DISK DRIVES
  23.      
  24.      
  25.      Installation of the controller requires three steps:  1) verifying 
  26.      jumper settings; 2) installing into the host computer; 3) formatting 
  27.      the hard disk drives.  To complete installation, you will need the 
  28.      following:
  29.      
  30.      Two hard disk cables (3 if using 2 hard disk drives); Winchester hard 
  31.      disk drive; screwdriver; MSDOS Version 2.0 or later; IBM Advanced 
  32.      Diagnostic diskette (or similar program for IBM compatibles); System 
  33.      Diagnostic Diskette (or equivalent); FDISK and Format utility 
  34.      (normally included with MSDOS).
  35.      
  36.                             Preparation of Controller
  37.      
  38.                                      WARNING
  39.                  HANDLE THE CONTROLLER BY THE ENDS OF THE BOARD
  40.                 SOME OF THE CHIPS ARE STATIC SENSITIVE AND DAMAGE
  41.                   MAY OCCUR IF THE BOARD IS INCORRECTLY HANDLED
  42.      
  43.      Before you can install your WD1003-RAH, you will need to be certain 
  44.      that the jumpers (small shorting plugs) are correctly set.  Refer to 
  45.      Table 1 for correct jumper settings.  Modification of factory jumper 
  46.      settings is rarely necessary.  Modify jumpers only under the 
  47.      direction of a qualified individual; i.e. your dealer.
  48.      
  49.  
  50.  
  51.  
  52.  
  53.  
  54.  
  55.  
  56.  
  57.  
  58.  
  59.  
  60.  
  61.  
  62.  
  63.  
  64.  
  65.  
  66.  
  67.      
  68.      
  69.      ┌──LED──────────────────────────────Drive 2─Drive 1─Control────────┐
  70.      │  ┌─J6   ∙∙∙W6                     ┌─J3──┐ ┌─J2─┐ ┌───J1───┐      │
  71.      │  └─┘    123         ┌U3─┐         └─────┘ └────┘ └────────┘      │
  72.      │         ∙∙∙W4       └───┘                                        │
  73.      │         123                    W2           1 2     1∙W5         │
  74.      │                                ∙ ∙       W1 ∙ ∙     2∙           │
  75.      │                                1 2   ┌──────┐ ┌──┐  3∙    ┌──┐   │ 
  76.      │                                      │ U8   │ └U9┘  1∙W3  U12┘   │
  77.      │      WD1003-RAH                      └──────┘       2∙           │
  78.      └───────────────────────────────┐          ┌──┐                ┌───┘
  79.                                      └┴┴┴┴┴┴┴┴┴┴┘  └┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┘
  80.      
  81.      
  82.                                      Table 1
  83.      
  84.      Jumper     Position      Function
  85.      
  86.      W1         1-2           Standard factory setting. Status read is 
  87.                               latched.  Used for IBM PC AT if Winchester
  88.                               activity LED is connected to J6.
  89.      
  90.                 Open          Status read is not latched. Activity LED 
  91.                               turns on during drive access. W5 must be 
  92.                               jumpered 2 to 3. Used for Compaq hosts.
  93.      
  94.      W2         Open          Standard factory setting. Selects primary
  95.                               addresses, 1F0 through 1F7 and 3F0 through
  96.                               3F7 hex. Do not modify the primary address
  97.                               jumper unless your BIOS operating system is
  98.                               configured to accept more than two hard disk 
  99.                               drives.
  100.      
  101.                 1-2           Selects secondary addresses, 170 through 177
  102.                               and 370 through 377 hex.
  103.      
  104.      W3         Open          This configuration used with WD11C00C-22 at 
  105.                               board location U8 or if W5 is jumpered 1 to 
  106.                               2
  107.      
  108.                 1-2           Required only on early units with WD11C00-22
  109.                               at board location U8 and W5 is jumpered 1 to
  110.                               2. DO NOT JUMPER WITH THE WD11C00C-22 
  111.                               INSTALLED.
  112.      
  113.  
  114.  
  115.  
  116.  
  117.  
  118.  
  119.  
  120.  
  121.  
  122.  
  123.  
  124.  
  125.  
  126.  
  127.  
  128.  
  129.  
  130.  
  131.  
  132.  
  133.      
  134.      W4         2-3           Standard factory setting. No translation for
  135.                               drive 0.
  136.      
  137.                 1-2           Enables translation for drive 0. Translation 
  138.                               is only available for 615 cylinders and four
  139.                               headed drives. In translation mode, the 
  140.                               controller translates the 26 physical 
  141.                               sectors per track into 17 sectors. The extra
  142.                               sectors are "translated" into logical heads.
  143.                               To use the translation mode, select through
  144.                               the Setup program a 615 cylinder and six 
  145.                               head drive type. (This is drive type 3 for
  146.                               IBM Personal Computer AT users. Not all AT-
  147.                               compatible systems use the same drive tables 
  148.                               as IBM.) This configuration must be used 
  149.                               when running an operating system or applica-
  150.                               tion program which requires a 17 sector per
  151.                               track disk drive.
  152.      
  153.      W5         2-3           Standard factory setting. WG and drive 
  154.                               select lines only enabled when drive is
  155.                               accessed. This configuration also provides
  156.                               power up and down protection.
  157.      
  158.                 1-2           WG and drive select lines are disabled 
  159.                               during power up reset and when +5V power
  160.                               supply drops below approximately +4.15V.
  161.      
  162.      W6         2-3           Standard factory setting. No translation
  163.                               for drive 1.
  164.      
  165.                 1-2           Enables translation for drive 1. Translation
  166.                               is only available for 615 cylinders and four
  167.                               headed drives. In translation mode, the
  168.                               controller translates the 26 physical 
  169.                               sectors per track into 17 sectors. The extra
  170.                               sectors are "translated" into logical heads.
  171.                               To use the translation mode, select through
  172.                               the Setup program a 615 cylinder and six 
  173.                               head drive type. (This is drive type 3 for
  174.                               IBM PC AT users. Not all AT-compatible 
  175.                               systems use the same drive tables as IBM).
  176.                               This configuration msut be used when running
  177.                               an operating system or application program
  178.                               which requires a 17 sector per track disk
  179.                               drive.
  180.      
  181.      
  182.           
  183.      
  184.  
  185.  
  186.  
  187.  
  188.  
  189.  
  190.  
  191.  
  192.  
  193.  
  194.  
  195.  
  196.  
  197.  
  198.  
  199.                               Hardware Installation
  200.      
  201.                                      WARNING
  202.                         MAKE SURE COMPUTER IS TURNED OFF
  203.                             AND POWER IS DISCONNECTED
  204.      
  205.      1.  Verify that your host computer has a 135 watt power supply.  If 
  206.      the disk drive(s) is(are) being installed internally, it is best to 
  207.      locate the controller in the nearest available expansion slot to the 
  208.      drive.
  209.      
  210.      2.  Remove the blank expansion slot bracket.  Put the bracket away 
  211.      and save it for possible future use.  The screw will be used to hold 
  212.      the new controller in place.
  213.      
  214.      3.  The terminating resistor must be present only on the last hard 
  215.      disk drive connected.  If there are two drives, the terminating 
  216.      resistor must be present on the second drive.  Verify proper setting 
  217.      of drive select switches for drive select 1 or 2. Refer to your 
  218.      system owner's manual for information about proper drive termination 
  219.      and select switches.
  220.      
  221.      4.  Attach 34-pin control connector pin 1 to J1 on the controller 
  222.      board.  Make sure that Pin 1 of the cable connector goes to Pin 1 on 
  223.      the controller board.  Pin 1 of the cable connector is typically 
  224.      located on the color coded side of the cable.
  225.      
  226.      5.   Connect control cable to drive.
  227.      
  228.      6.   Attach 20-pin data connector to J2 (Drive C or 0).
  229.      
  230.      7.   Attach 20-pin data connector to J3 (Drive D or 1).
  231.      
  232.      8.   Connect data cables to drives.
  233.      
  234.      9.   Attach Winchester activity LED connector to J6.
  235.      
  236.      10.  Install controller board into the expansion slot. Make sure that 
  237.      the board is seated properly by pressing down on both ends of the 
  238.      board.  Secure the board with the bracket screw.
  239.      
  240.                                      CAUTION
  241.                   WHEN ROUTING CABLES, BE CAREFUL NOT TO PINCH
  242.                   THEM.  CABLES MUST NOT GET CAUGHT BETWEEN THE
  243.                  COVER AND THE BOARDS, NOR SHOULD THEY OBSTRUCT
  244.                       ANY AIR FLOW PATH FROM FANS OR VENTS.
  245.